The base controller holds the settings for all shutters. Each shutter has its own settings and can override any setting of the base schedule.

Where How to open it
Sources Smart Shutter Control → ⋮ → Reconfigure
Base settings Smart Shutter Control → Configure (menu)
A shutter the shutter's line on the integration page → Reconfigure (menu)

Sources

Setting Default Effect
Outdoor temperature required frost, heat protection, temperature limits, winter mode
Weather – fallback for "is it sunny?" without a sun source, or without its values
Sun source PV power PV power, Light sensors (lux) or None: what tells whether the sun shines (see How it works). Never both; a second page shows only the fields of the chosen source
Wind speed sensor – storm detection
Wind gust sensor – storm detection

Sensors may report in any unit Home Assistant knows: temperatures (outdoor, room, the weather forecast) are converted to °C and wind speeds to km/h when read, so a sensor in °F or mph works. A value without a unit counts as °C or km/h. The settings are shown and entered in your unit system: in °C and km/h with metric units, in °F and mph with US customary units (they are stored in °C and km/h, so switching unit systems keeps them). Length settings are also shown in your unit system: in cm and m with metric units, in inches and feet with US customary units (they are stored in cm and m). The defaults below are given in °C and km/h.

Changing the sun source with Reconfigure leaves out the fields of the other source: a base controller never keeps PV sensors and light sensors together. Pick the source, then fill in its page.

Sun source PV power:

PV peak power: count the panels, not the inverter

20 panels of 400 Wp are 8 kWp, also when the inverter is rated 6 kW. With two systems whose sensors are added up (a house roof and a garage roof), enter the panels of both. A value that is too low makes the expected power too low, so the sun factor reaches 100 % on a hazy day and heat or glare protection starts too easily while the integration is still learning.

Setting Default Effect
PV power sensors required one or more, added up
PV peak power (kWp) – the total peak power of the panels behind the PV power sensors: the sum of their Wp ratings, not the inverter's rating. Used for a rough clear-sky curve while the learned reference is young (see Learning)
Panel tilt 35° degrees from horizontal (0 = flat, 90 = vertical), for that curve
Panel direction 180° where the panels face (0 = north, 90 = east, 180 = south, 270 = west), for that curve

Sun source Light sensors (lux):

Setting Default Effect
Light sensors required one or more illuminance sensors; the highest value counts. The page shows each sensor's highest value of the last 30 days, and warns once when one stays below 10 000 lx (it probably saturates)
Sunny from (until learned) 30 000 lx sunny from this while the learned reference is young (20 % hysteresis)

Base settings (Configure)

Schedule

The base schedule: every shutter follows it unless it overrides a setting (see Schedule overrides).

Base controller Schedule options

Setting Default Effect
Slit on weekdays 08:00 start of the slit phase on working days
Open on weekdays 08:30 start of the day phase on working days
Slit on weekends and holidays 10:00 the same on weekend days and holidays
Open on weekends and holidays 10:30 the same on weekend days and holidays
Slit phase on off: no slit phase, straight from night to day
Not before sunrise off on: slit and open wait for sunrise (+ minutes after sunrise) when that is later
Minutes after sunrise 0 only with Not before sunrise; −120 to 120
Dusk phase on off: no dusk phase, straight from day to night
Dusk: minutes after sunset 0 start of the dusk phase; −120 to 120. A dusk that would start at or after the close time is left out
Dusk position 35 % position during dusk
Close: minutes after sunset 15 start of the night; −120 to 180
Close not before – the night never starts earlier than this
Close not after – the night never starts later than this. Also used instead of sunset where the sun does not set (polar day or night); without it 21:00
Open position 100 % position during the day (never above the shutter's maximum position)
Slit (module position, uncalibrated) 20 % the slit for shutters that are not calibrated; a calibrated shutter uses its measured lift point (see Calibration)
Sleep in until 12:00 sleep-in ends at the latest at this time. A sleep-in switched on after this time today is for tomorrow morning
After a manual action pause until the next phase pause until the next phase, pause for a while or ignore (see manual operation)
Pause after a manual action 120 min only for pause for a while
Storm position nearest nearest end, always open or always closed during a storm
Winter mode on off: winter mode does not apply
Winter: closed all day at or below −5 °C in winter the shutter stays closed all day at or below this outdoor temperature; empty: off

Examples (defaults: slit 08:00, open 08:30, dusk 0 min and close 15 min after sunset):

Situation Result
Summer weekday, sunset 21:40 night until 08:00, slit 08:00, day 08:30, dusk 21:40 (35 %), night 21:55
Close not after 21:30, same evening the close time 21:55 becomes 21:30, which is before the dusk time 21:40: no dusk phase, day goes straight to night at 21:30
Winter weekday, sunset 16:30, Close not before 18:00 day until dusk at 16:30 (35 %), night at 18:00 instead of 16:45
Not before sunrise on, sunrise 08:10, 0 minutes slit 08:10 (not 08:00), day 08:30
Same, sunrise 08:40 the slit would start at 08:40, together with the day: the slit is skipped, night goes straight to day at 08:40
Sunday the weekend times: slit 10:00, day 10:30

Holidays

On weekend days and holidays the schedules use their weekend times. The page has two steps.

Base controller Holidays options, step 1

Setting Default Effect
Public holidays calendar – a calendar entity, for example of Home Assistant's Holiday integration
Weekend days Saturday, Sunday days that always use the weekend times
Calendar holidays to ignore – check boxes with the calendar's holidays; checked ones count as normal days every year
Extra holidays – one per line: 2026-12-24 (once) or 12-31 (every year), optionally followed by a name
Not a holiday – dates from the calendar that count as normal days, same format

The calendar is read when Home Assistant has started, when the calendar becomes available, and every night.

Example: Extra holidays with the two lines below make 24 December 2026 a one-off free day, and 31 December (every year) too. Not a holiday with 05-05 makes 5 May a normal working day, also when the calendar lists it.

2026-12-24 Christmas Eve
12-31 New Year's Eve

A line that cannot be read stops the page with an error naming the line numbers.

Sun

Base controller Sun options

Setting Default Effect
Sunny from 60 % PV power or light (lux) as a share of its clear-sky value above which it counts as sunny (−15 % hysteresis). With light sensors, the fixed Sunny from (until learned) limit in lux applies until the clear-sky value is learned
Largest angle of incidence 85° sun at a larger angle to the window does not count as shining on it
Heat protection from (outdoor) 22 °C heat protection only acts at or above this outdoor temperature, or …
Heat protection from (room) 24 °C … at or above this room temperature (shutters with a room sensor)
Hot day from (forecast) 28 °C forecast maximum at or above which heat protection no longer waits for the outdoor or room temperature; empty: off
Close after 5 min sun on the window this long before the shutter goes down
Open after 20 min no sun this long before it goes up again

Storm and frost

Base controller Storm and frost options

Setting Default Effect
Storm: wind speed from 50 km/h storm at or above this wind speed; empty: not used. The page shows the highest value of the last 30 days
Storm: gusts from 60 km/h the same for gusts
Storm ends after 15 min after the last value above a limit
Frost at or below 0 °C during frost shutters do not move automatically
Frost ends after 60 min after the temperature rose above the limit
Close above – outdoor temperature above which shutters close, until it is 1 °C lower again; empty: off
Close below – outdoor temperature below which shutters close, until it is 1 °C higher again; empty: off

Close above and Close below come before a manual pause: a shutter you open by hand is closed again while the limit applies (see which rule wins).

Winter

Base controller Winter options

Setting Default Effect
Winter below (24-hour mean) 12 °C winter mode is on while the time-weighted mean outdoor temperature of the last 24 hours is below this (1 °C hysteresis), with the select Winter mode on Auto

Away and holiday

When nobody is home the heat can be kept out earlier and glare does not matter; on holiday the schedule times also shift a little each day so the house looks lived in. See Away and holiday.

Base controller Away and holiday options

Setting Default Effect
Presence entity none a zone.home (counts the persons in the zone), a person or device_tracker, a group or a binary_sensor (on: somebody is home). Empty: the house is never away, unless the Holiday switch is on
Away after 15 min how long nobody must be home before the house counts as away; coming home counts at once
Away: heat protection lower by 3 °C both heat limits (outdoor and room) are this much lower while away
Holiday: time shift up to 30 min the largest random shift of the schedule times on holiday; 0: no shift

Language

Base controller Language options

Setting Default Effect
Language System language the language of the card and of the entity names: system, English or Nederlands. Settings screens and state values in Home Assistant's own cards always follow your profile language

A shutter

Reconfigure opens a menu: Settings, Schedule overrides, Reset to the base schedule, Calibrate (the assistant, or a table of the measured points; see Calibration), Add a calibration point, Horizon and Window and door contacts.

Settings

A shutter's Settings

Setting Default Effect
Shutter required the cover entity that moves the shutter; it must support a position
Name the cover's name the name of the shutter's device
Window direction required degrees, 0 = north, 90 = east, 180 = south, 270 = west: the direction the glass faces (see examples)
Window tilt 90° degrees from horizontal: 90 = vertical, 0 = flat; less for a roof window
Lowest sun elevation 0° below this the sun is blocked (buildings, trees); a horizon can raise it per direction. Must be below the highest
Highest sun elevation 90° above this the sun is blocked (an overhang, a balcony)
Room temperature sensor – for Heat protection from (room)
Motor power sensor found on the cover's device tells when the motor runs: used by the calibration and to recognise manual moves at once
Travel time – seconds from fully open to fully closed; measured by the calibration when there is no motor power sensor
Maximum position 100 % automatic control never opens the shutter further; by hand it can. Below 100 % the shutter closes in a storm (see examples)
Heat protection on lower the shutter when the sun shines on the window and it is warm
Heat protection position 30 % position during heat protection; with the three room fields below the lowest it uses
Window bottom above the floor – cm (inches with US customary units); with Window height and Sun into the room: the shading position follows the sun
Window height the calibration's cm (inches with US customary units); the height of the glass
Sun into the room – m (feet with US customary units); direct sun may reach this far over the floor
Heat protection from (outdoor) the base value override for this shutter
Heat protection from (room) the base value override for this shutter
Hot day from (forecast) the base value override of the base forecast limit; empty: the base value
Glare protection off lower the shutter when bright sun shines on the window, whatever the temperature (see Glare protection)
Glare position 40 % position during glare protection; with the room fields the lowest it uses
Glare from 70 % sun factor from which the sun counts as bright
Facade light sensor – only with the sun source Light sensors: a light sensor at this window that decides for this shutter whether it is sunny

The form refuses a cover that cannot be set to a position, a cover that already has a shutter controller, and a Lowest sun elevation that is not below the Highest sun elevation.

Settings that are also entities. Maximum position, Heat protection, Heat protection position, Glare protection, Glare position and Glare from are entities of the shutter too (see Entities). The value in Settings is where the entity starts. Once you change the entity (a dashboard, an automation), the entity's value is kept and the form no longer changes it: change it through the entity from then on.

Window and door contacts

All fields are optional. The contacts keep the shutter clear of an open door or give a tilted window a gap.

A shutter's Window and door contacts

Setting Default Effect
Opened contact – binary sensor; on means the door or window is open
Tilted contact – binary sensor; on means the window is tilted
Lockout position 100 % while opened, automatic control keeps the shutter at least this high
Ventilation position the slit while tilted, automatic control keeps the shutter at least this high (%)

How the floors behave, with a timeline, is under Lockout and ventilation.

Horizon

A shutter's Horizon table

A table with a row per point: Sun direction (°) (0 to 360) and Lowest elevation (°) (0 to 60). The button Sun has left the window adds points; here you can correct, add or remove them. A direction may appear only once. Leave the table empty for no horizon. See Sun on the window and the example.

Schedule overrides

The same fields as the base schedule. Every field is empty or Inherit by default: the shutter then follows the base schedule, whose value is shown under the field. Fill in a value to override that one setting. Reset to the base schedule clears all overrides of the shutter.

The sensor Next action has an attribute overrides listing what the shutter overrides.

Examples

Worked examples for the settings that are hardest to get right. The shutters are made up: cover.living_room, cover.bedroom.

Window direction, tilt and sun elevations

The window direction is the direction the glass faces: look out of the window, the compass reading in front of you is the direction. Lay a compass app flat against the glass, top edge pointing outward.

The window of cover.living_room faces Window direction
north-east 45°
south 180°
a little west of south (20°) 200°
south-west 225°

The sun counts as on the window when its angle of incidence is below the Largest angle of incidence (85°). For a south window (180°) with a vertical glass:

Sun azimuth Sun elevation Angle of incidence On the window?
150° 30° 41° yes
255° 20° 76° yes
265° 20° 85.3° no, just past the limit
270° (due west) 10° 90° no: the sun is in the plane of the glass

A roof window on a south slope with a 40° pitch has Window direction 180° and Window tilt 40°. The sun at azimuth 180° and elevation 50° then shines straight onto the glass (0°). (A window with a tilt other than 90° uses the fixed heat protection and glare positions: the room geometry below only works for vertical glass.)

Lowest sun elevation and Highest sun elevation block the sun by height:

  • The roof of the neighbour's house reaches 12° above the horizon as seen from the window: set Lowest sun elevation to 12. A sun below 12° is not on the window, so heat protection does not start for it.
  • The balcony above the window keeps the sun off the glass once it is higher than 55°: set Highest sun elevation to 55.

For a blocker that is high in one direction and low in another, use the horizon.

Maximum position

cover.bedroom has a Maximum position of 80 %, because the shutter is stopped by a plant on the sill when fully open. Then:

What asks for a position Result
the schedule, Open position 100 % 80 %
heat protection, Heat protection position 30 % 30 % (the maximum only limits upward)
the schedule closes the shutter (night, 0 %) 0 %: closing is never limited
you drag the card or press open on the cover 100 %: by hand it can go further
the action set_lock with force_open 100 %: an explicit order
an opened door contact with Lockout position 100 % 100 %: safety goes first
a tilted window contact with Ventilation position 90 % 80 %: comfort stays within the maximum
storm 0 %: below 100 % the shutter closes in a storm, because there is no safe open end

Shading depth and room geometry

Heat and glare protection normally go to a fixed position (Heat protection position, Glare position). With three room measurements they go down only as far as needed. The living room: the glass starts 90 cm above the floor (Window bottom above the floor 90), is 150 cm high (Window height 150), and direct sun may reach 2 m into the room (Sun into the room 2), for example up to the sofa. Heat protection position is 30 %. For a south window and the sun straight in front of it:

Sun elevation Position that keeps the sun within 2 m Used (rounded down to 10 %, at least 30 %)
25° 2 % 30 %
30° 17 % 30 %
40° 52 % 50 %
45° 73 % 70 %
50° 99 % 90 %
55° 100 % 100 % (the shutter stays open)

Sun that comes in at an angle is longer on its way to the floor: at elevation 40° with the sun 45° to the side the position is 98 %, used 90 %. The position changes at most once per 15 minutes. The formula is in How it works.

Horizon profile

Buildings and trees block a low sun at different heights per direction. On a clear evening, when the sun disappears behind something while heat or glare protection holds the shutter down, press the button Sun has left the window. The sun's direction and its elevation (plus 0.1°) become a point. Say you record two points over two evenings: direction 200° at elevation 25.0° (a tall tree) and direction 230° at 12.0° (a lower roof). Lowest sun elevation is 0°:

Sun direction Horizon used Why
184° none (0°) more than 15° before the first point
185° 25.0° the first point holds 15° before itself
200° 25.0° the point
215° 18.5° halfway between the two points: 25 − (25 − 12) × 15 / 30
230° to 245° 12.0° the last point holds 15° further
246° none (0°) more than 15° after the last point

The higher of the horizon and Lowest sun elevation counts: with a Lowest sun elevation of 15°, the sun at direction 235° needs more than 15°, not 12°. A new point within 3° of direction of an existing one replaces it. Reconfigure → Horizon shows the table to correct it.